INDUSTRIAL WATER TREATMENT ›› 2005, Vol. 25 ›› Issue (5): 38-41. doi: 10.11894/1005-829x.2005.25(5).38

Previous Articles     Next Articles

Study on the combination of advanced oxidation process and the reuse of municipal wastewater

Zhou Tao1, Jiang Junqing2, Ai Zhihui1, Yang Peng1, Lu Xiaohua1   

  1. 1. Environmental Science Research Institute, Huazhong University of Science and Technology, Wuhan 430074,China;

    2. Electric Power Construction Insititute, National Electric Power Company, Beijing 100055,China
  • Received:2004-12-20 Online:2005-05-20 Published:2010-10-01

城市生活污水回用于电厂的组合高级氧化技术

周涛1, 姜军清2, 艾智慧1, 杨鹏1, 陆晓华1   

  1. 1. 华中科技大学环境科学研究所, 湖北武汉 430074;
    2. 国电电力建设研究所, 北京 100055
  • 作者简介:周涛(1979-),华中科技大学环境学院在读硕士生,主要研究方向为水污染控制技术电话:027 -87544091,87555926,手机:13545128945通讯联系人:陆晓华,E-mail :lxh@hust-esri.com
  • 基金资助:

    科技部2002年度科技项目,编号EPCRI-K2005

Abstract:

The removal rate of COD and NH3 - N from municipal wastewater with the combination technologies of advanced oxidation:UV/O3、UV/TiO2 and UV/O3/TiO2 are compared. The operation parameters of UV/O3/TiO2 are optimized.The results show that the technology of UV/O3/TiO2 is more efficient for the removal of COD and NH3 - N. Within 2 h,the removal rate of COD and NH3 - N can be 90% and 70% respectively. The treated water can be reused in electric power plant.

Key words: municipal wastewater, reuse, advanced oxidation processes

摘要:

通过实验研究比较了UV/O3、UV/TiO2以及UV/O3/TiO2等三种高级氧化技术对城市生活污水中COD和NH3-N的去除效率,重点确定了UV/O3/TiO2法的主要工艺参数。研究结果表明,对于COD、NH3-N质量浓度分别为80~200mg/L和15~25mg/L的城市污水处理厂初沉池出水,用UV/O3/TiO2法处理2h后,COD去除率达到90%,NH3-N去除率达到70%,基本达到了回用于电厂的要求。

关键词: 城市生活污水, 回用, 高级氧化

CLC Number: