Abstract:
The determination of mercury in water with atomic fluorescence spectrometer has been studied. The experimental results are satisfactory when the determination conditions are:5% hydrochloric acid is used as carrier liquid and 10 g/L potassium borohydride is used as reductant,etc.
Key words:
atomic fluorescence spectrometer,
mercury,
determination conditions
摘要:
对原子荧光光度计检测水中汞进行了研究,发现使用5%的盐酸做载流液,10 g/L的硼氢化钾溶液做还原剂等检测条件下,其实验结果令人满意。
关键词:
原子荧光光度计,
汞,
检测条件
CLC Number:
Wang Yanman. Study on the determination of mercury in water with atomic fluorescence spectrometer[J]. INDUSTRIAL WATER TREATMENT, 2010, 30(5): 72-74.