INDUSTRIAL WATER TREATMENT ›› 2017, Vol. 37 ›› Issue (5): 98-100. doi: 10.11894/1005-829x.2017.37(5).098

Previous Articles     Next Articles

Reuse project on the treatment of low-concentration printing and dyeing wastewater by hydrolytic acidification+A/O+UF+RO hybrid process

Cheng Jiadi1, Huang Zhouman2   

  1. 1. Tongxiang Environmental Protection Bureau, Tongxiang 314500, China;
    2. School of Life Science, Wuchang University of Technology, Wuhan 430223, China
  • Received:2017-03-23 Revised:2017-03-23 Online:2017-05-20 Published:2017-06-03

水解酸化+A/O+UF+RO处理低浓度印染废水回用工程

程家迪1, 黄周满2   

  1. 1. 桐乡市环保局, 浙江桐乡 314500;
    2. 武昌理工学院生命科学学院, 湖北武汉 430223
  • 通讯作者: 黄周满,硕士,讲师。E-mail:zmhuang0826@163.com。 E-mail:zmhuang0826@163.com
  • 作者简介:程家迪(1984-),硕士,工程师。E-mail:jiadi613@163.com。

Abstract:

The combined process,hydrolytic acidification+A/O+ultra-filtration+reverse osmosis has been used for up-grading modification and reuse of the 1 500 m3/d low-concentration printing and dyeing wastewater in a printing plant in Jiaxing. The results show that when the average COD,chroma and SS in influent are 450 mg/L,80 times and 600 mg/L,respectively,those of RO effluent are 15 mg/L,3 times and 1 mg/L,respectively,and the system removing rates are 96.7%,96.3% and 99.8% respectively. The concentration of each index is below the designed recycling water standard. The total investment of this project is RMB 4 897 800.00,operation cost RMB 3.53 per cubic meter. The system recycling rate has been maintained at about 53% for the year past,water saving 240 000 tons per year, and reduced expense more than RMB 1500 000.00.

Key words: low-concentration printing and dyeing wastewater, reuse, ultra-filtration, reverse osmosis

摘要:

嘉兴某印染企业采用“水解酸化+A/O+超滤+反渗透”组合工艺对1500 m3/d低浓度印染废水处理装置进行深度处理及回用改造。结果表明:在进水COD、色度和SS均值分别为450 mg/L、80倍和600 mg/L时,RO出水COD、色度和SS分别为15 mg/L、3倍和1 mg/L,系统COD、色度和SS去除率分别达96.7%、96.3%和99.8%。工程总投资489.78万元,运行成本3.53元/m3。一年来系统回用率稳定在53%左右,年节约用水24万t,年减少支出150万余元。

关键词: 低浓度印染废水, 回用, 超滤, 反渗透

CLC Number: