Industrial Water Treatment ›› 2020, Vol. 40 ›› Issue (2): 36-40. doi: 10.11894/iwt.2019-0133

• RESEARCH AND EXPERIMENT • Previous Articles     Next Articles

Electrochemical method for reducing Fe3+ from iron-rich sludge in pulp mill

Jingwei Zhang1(),Zhouyang Bai1,Qiang Ge2,Suji Tan1,Hao Xu1,Shucheng Yang1,*()   

  1. 1. School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    2. China CEC Engineering Corporation, Changsha 410114, China
  • Received:2019-12-03 Online:2020-02-20 Published:2020-02-22
  • Contact: Shucheng Yang E-mail:zhangjing0804@stu.xjtu.edu.cn;yanyang@mail.xjtu.edu.cn
  • Supported by:
    国家自然科学基金资助项目(51308453);中国轻工业长沙工程有限公司资助项目(20150987)

制浆造纸厂富铁污泥中Fe3+的电化学还原研究

张婧伟1(),白周央1,葛强2,谭苏吉1,徐浩1,杨树成1,*()   

  1. 1. 西安交通大学能源与动力工程学院, 陕西西安 710049
    2. 中国轻工业长沙工程有限公司, 湖南长沙 410114
  • 通讯作者: 杨树成 E-mail:zhangjing0804@stu.xjtu.edu.cn;yanyang@mail.xjtu.edu.cn
  • 作者简介:张婧伟(1995-),在读硕士研究生。E-mail:zhangjing0804@stu.xjtu.edu.cn
  • 基金资助:
    国家自然科学基金资助项目(51308453);中国轻工业长沙工程有限公司资助项目(20150987)

Abstract:

Electrochemical method was used to reduce Fe3+ to Fe2+ in the refractory iron-rich sludge that were produced in the Fenton oxidation process of pulp and paper wastewater for its subsequent reuse. The results indicated that the stainless steel cathode could significantly reduce the overpotential of Fe3+ reduction. When the concentration of Fe3+ was 2 000 mg/L, auxiliary electrolyte was not needed. After two hours of the electrochemical reduction under the condition that the ratio of cathode area to water volume was 0.48 cm2/mL and current density was 0.65 mA/cm2, the Fe2+ regeneration rate reached 60.1%, and the corresponding current efficiency was 92.1%. The acid-treated iron-rich sludge solution was also reduced under this condition for three hours. The Fe2+ regeneration rate could reach 68.8%, and the current efficiency was close to 100%. The electrochemical reduction is a feasible method for the recovery of Fe3+ in iron-rich sludge.

Key words: iron-rich sludge, electrochemical reduction, pulp and paper, Fenton oxidation

摘要:

采用电化学法将制浆造纸厂废水Fenton氧化产生的难处理富铁污泥中的Fe3+还原为Fe2+,以便于其再利用。研究表明,以不锈钢为阴极材料可较大幅度降低Fe3+还原的过电位;当Fe3+质量浓度为2 000 mg/L时无需辅助电解质,在极水比为0.48 cm2/mL,电流密度为0.65 mA/cm2的条件下反应2 h,Fe2+再生率可达60.1%,电流效率为92.1%。将酸处理后的富铁污泥溶液在上述条件下还原3 h,Fe2+再生率达68.8%,电流效率近100%。电化学法是富铁污泥中Fe3+再利用的可行方法。

关键词: 富铁污泥, 电化学还原, 制浆造纸, Fenton氧化

CLC Number: