Industrial Water Treatment ›› 2020, Vol. 40 ›› Issue (7): 98-102. doi: 10.11894/iwt.2019-0595

• Research and Experiment • Previous Articles     Next Articles

Statistical diagnosis of performance of wastewater treatment plant

Jie Fan1(),Liang Cao1,Cheng Gao1,Jiasong Ye1,Wenning Ye2   

  1. 1. College of Urban Construction, Wuhan University of Science and Technology, Wuhan 430065, China
    2. Yingtan Shouchuang Water Group, Yingtan 335000, China
  • Received:2020-04-26 Online:2020-07-20 Published:2020-07-21

基于统计学分析的污水厂运行性能诊断

樊杰1(),曹亮1,高乘1,叶佳松1,叶文宁2   

  1. 1. 武汉科技大学城市建设学院, 湖北武汉 430065
    2. 江西省鹰潭首创水务, 江西鹰潭 335000
  • 作者简介:樊杰(1981-), 博士, 副教授。电话:15927015002, E-mail:fanjie0714@163.com

Abstract:

Statistical methods of descriptive statistics, correlation and principal component analysis were used to analyze the stability, potential for upgrading, abnormal working conditions and optimization of the oxidation ditch process of a sewage plant were analyzed. Results showed the TP and TN removal rates of low-concentration sewage were unstable due to the process. MLSS, phosphorus concentration in the influent and DO were the key factors to increase the TP removal rate. Deficient carbon source and poor resistance to TN loading limited the TN removal. The decline of temperature in winter caused sludge bulking. Viscous sludge bulking accompanied with reduced removal of SS and COD, while filamentous sludge bulking accompanied with reduced removal of NH3-N. To achieve discharging standard, TP and SS need more emphasis.

Key words: wastewater treatment plant, statistical analysis, sludge bulking, diagnosis

摘要:

采用描述性统计、相关性和主成分法,分析了某污水厂氧化沟工艺的稳定性、提标潜力、异常工况和优化。结果表明:工艺对低浓度污水的TP和TN去除率不稳定,MLSS、进水磷浓度和DO是提高TP去除率的关键,碳源不足和抗TN冲击负荷能力差影响TN去除。冬季降温引发污泥膨胀,黏性膨胀时SS和COD去除效果下降,丝状菌膨胀时氨氮去除效果下降。提标改造的重点在TP和SS。

关键词: 污水厂, 统计学分析, 污泥膨胀, 诊断