INDUSTRIAL WATER TREATMENT ›› 2000, Vol. 20 ›› Issue (8): 26-28. doi: 10.11894/1005-829x.2000.20(8).26

Previous Articles     Next Articles

Experimental researches on the treatment of anaerobic effluent by coagulator-flocculation

HUANG Zhenlan, LI Xiying, YANG Yifeng, WUXiao, ZHANG Zhongmin   

  1. The Research Institute of Energy Resources, Jiangxi Academy of Sciences, Nanchang 330029, China
  • Received:1999-06-20 Online:2000-08-20 Published:2010-10-01

用化学混凝沉降法处理厌氧出水的试验研究

黄贞岚, 李锡英, 杨沂凤, 吴晓, 张忠民   

  1. 江西省科学院能源所, 江西南昌 330029
  • 作者简介:黄贞岚(1965- ), 1988 年毕业于同济大学, 助理研究员。

Abstract:

This paper introduces experimental researches on the treatment of anaero bicef fluent of highly concent rated or ganic wasterw ater by coag ulator-floculation process. The optimal coagulator and optimalpr ocessing conditions are determined by experiments. The results show that the dosage and cost of theirt riturated cogulator are the lowest, COD removal rate is over 86%, SS removal rate is over 90%, and the end effluent meets the discharge standard. The floc formed has better sedimentation property, and easily be separ ated from water. After the highly concent rated organic wastewater having been tr eated by anaerobict reatment, the chemical coagulation can be carried through directly. The aerobict reatment is omitted. This makes the technique simpler and the cost lower.

Key words: coagulation-f locculation, chemical coagulator, anaerobic effluent, COD removal rate

摘要:

介绍了用化学混凝沉降法处理高浓度有机废水的厌氧出水的试验研究。通过试验选择最佳絮凝剂及其使用的工艺条件。结果表明,使用该所研制的KN-絮凝剂处理厌氧出水,絮凝剂的用量、费用最低,COD去除率达到86%以上,SS去除率达到90%以上,最终出水达到国家排放标准。并且产生的絮状物沉降性能好,容易从水中分离出来。此工艺的特点是高浓度有机废水经过厌氧处理后直接进行化学混凝,省去了好氧处理,处理工艺更加简单,运行费用大大降低,在工业水处理中具有广阔的应用前景。

关键词: 化学混凝沉降法, 化学混凝剂, 厌氧出水, COD去除率