INDUSTRIAL WATER TREATMENT ›› 2001, Vol. 21 ›› Issue (8): 36-37. doi: 10.11894/1005-829x.2001.21(8).36

Previous Articles     Next Articles

Analysis of and countermeasures to the water quality deterioration in mechanical filter output

HUANG Xiaochun1, HU Qun2   

  1. 1. Linhuan Gangue Heat and Power Plant, Huaibei 235136, China;
    2. Zhangzhuang Coalliery Gangue Heat and Power Plant, Huaibei 235047, China
  • Received:2001-02-06 Online:2001-08-20 Published:2010-10-01

机械过滤器出水水质恶化分析及对策

黄校春1, 胡群2   

  1. 1. 临涣煤矸石热电厂, 安徽淮北 235136;
    2. 张庄矿矸石热电厂, 安徽淮北 235047
  • 作者简介:黄校春(1975- ),1998年毕业于武汉水利电力大学动力与机械工程学院电厂化学专业,助理工程师.电话:0561-4985221或4984997转2183.

Abstract:

The phenomenon of the water quality deterioration in mechanical filter output, since Linhuan Gangue Heat and Power Plant has undergone the test,is introduced.The causes for the water quality deterioration in the mechanical filter output are analyzed and the countermeasures of it are put forward.

Key words: mechanical filter, water quality deterioration, analysis

摘要:

介绍了临涣煤矸石热电厂自调试以来机械过滤器出水水质恶化的现象,分析了出水水质恶化的原因,提出了相应的处理对策。

关键词: 机械过滤器, 水质恶化, 分析