INDUSTRIAL WATER TREATMENT ›› 2006, Vol. 26 ›› Issue (10): 39-43. doi: 10.11894/1005-829x.2006.26(10).39

Previous Articles     Next Articles

Study on influence of water temperature on hydrolytic anoxic baffled reactor in treating printing and dyeing was tewater

Wu Huifang1,2, Wang Shihe1, Xia Mingfang3, Lu Jilai3, Yin Xiedong3   

  1. 1. Department of Municipal Engineering, Southeast University, Nanjing 210096, China;
    2. College of Urban Construction and Safety & Environmental Engineering, Nanjing University of Technology, Nanjing 210009, China;
    3. Key Laboratory of Environmental Engineering of Jiangsu Province, Nanjing 210078, China
  • Received:2006-06-25 Online:2006-10-20 Published:2010-10-01

ABR处理印染废水水温影响特性及降解模型

吴慧芳1,2, 王世和1, 夏明芳3, 陆继来3, 尹协东3   

  1. 1. 东南大学市政工程系, 江苏南京 210096;
    2. 南京工业大学城市建设与安全环境学院, 江苏南京 210009;
    3. 江苏省环境工程重点实验室, 江苏南京 210078
  • 作者简介:吴慧芳(1972- ),1998 年毕业于东南大学,硕士,在职博士生,讲师。电话:13912987765,E-mail:whfkhl@sina.com。
  • 基金资助:

    江苏省环境工程重点实验室开放课题(KF-2004-04)

Abstract:

Experimental studies on printing and dyeing wastewater by using anoxic baffled reactor have been made, while water temperature is 5, 9.7, 14.9, 19.7 ℃ respectively. The results show that raising water temperature could help in raising removal rates of COD and chroma and could result in decreasing ORP, increasing pH value and better hydrolytic efficiency. Besides these, it is indicated that hydrolytic efficiency is worse at 5 ℃while it is better from 10 ℃ to 20 ℃. Moreover, in the temperature range of 5-20 ℃, the organic matter degradation in the reactor submits to the first grade kinetics by kinetic analysis, and the temperature coefficient is 24.07 kJ/mol.

Key words: printing and dyeing wastewater, anoxic baffled reactor, temperature coefficient

摘要:

在水温分别为5、9.7、14.9、19.7℃的条件下,应用折流式水解反应器(ABR)对印染废水进行水解试验。结果表明,提高水温可增大COD和色度的去除效率,相应的氧化还原电位(ORP)变小,pH升高,水解程度加深。水温5℃时,水解效果较差;水温在10~20℃内,水解效果相对较好。此外,通过动力学分析,在5~20℃内,该反应器中有机物降解服从一级动力学,其温度系数为24.07 kJ/mol。

关键词: 印染废水, 折流式水解反应器, 温度系数

CLC Number: