Abstract:
AB process has been used for treating beverage wastewater.The reflux sludge of section A is aeration oxygenated forcibly.Thus,the organisms are in endogenous metabolic period,the biological activity and adsorbing capacity of microorganisms are reinforced and the organism removing rate of section A is improved.As a result,even when the influent COD is 1 000 mg/L,the effluent can still reach the discharge standard.The project commissioning runs well.After the reflux sludge in section A is reinforced and regenerated,the COD removing rate reaches 70% over.The effluent COD of section B is 72 mg/L averagely.The design requirements are met completely.At the same time,the reinforcing and regeneration of sludge provide important guarantee for save and reliable operation of the system.
Key words:
AB process,
reinforced regeneration,
beverage wastewater
摘要:
采用AB法处理某饮料企业废水,通过对A段回流污泥采用强制曝气充氧使微生物处于内源代谢期,增强微生物的生物活性和吸附能力,提高A段有机物的去除率,使得企业即使在进水COD达到1 000 mg/L情况下亦能达标排放。工程调试运行结果良好,A段回流污泥强化再生后COD的去除率能达到70%以上,B段出水COD平均72 mg/L,完全满足设计要求。同时,污泥的强化再生为系统的安全可靠运行提供了重要保障。
关键词:
AB法,
强化再生,
饮料废水
CLC Number:
Sun Zhihua, Wu Zhongqin, Jiang Shuguang, Xu Feng. Example of the application of section A of AB process to the reinforced treatment of beverage wastewater[J]. INDUSTRIAL WATER TREATMENT, 2013, 33(7): 83-85.
孙志华, 吴中琴, 姜曙光, 徐凤. AB法A段强化再生处理饮料废水的应用实例[J]. 工业水处理, 2013, 33(7): 83-85.