工业水处理 ›› 2000, Vol. 20 ›› Issue (12): 42-44. doi: 10.11894/1005-829x.2000.20(12).42

• 经验交流 • 上一篇    下一篇

三循板式换热器堵塞原因分析及对策

黄加东   

  1. 中石化南京化学工业有限公司生产处, 江苏南京 210048
  • 收稿日期:2000-08-04 出版日期:2000-12-20 发布日期:2014-09-29
  • 作者简介:黄加东(1968- ),1989 年毕业于湖南大学, 工程师。

Analysis of the reasons for board-type heat-exchanger jam and its counter-move

Hjuang Jiadong   

  1. Production Department, Nanjing Chemical Industry Co., Ltd., of Petro chemical Industry, Nanjing 210048, China
  • Received:2000-08-04 Online:2000-12-20 Published:2014-09-29

摘要:

为解决板式换热器因被堵塞造成连续运行时间短的问题 ,从药剂配方、投加方式以及运行工艺等方面分析原因并进行调整 ,解决了板式换热器堵塞问题 ,板式换热器原来只能连续运行 144h ,现已能连续运行 1430h ,确认乙厂药剂适合于这套循环水装置。

关键词: 板式换热器, 堵塞, 系统调整

Abstract:

In order to solve the problem that board-type heat-exchanger couldn't run cont inuously for along time due to getting jammed easily .The reasons of it are analyzed and adjusted in respect of the component of chemicals , the ways of feeding and the running techniques .In the past the board-type heat-ex changer could only run 144 hours continuously .Now it can run 1 430 hours continuously .It is confirmed that the chemicals of Plant B is fit for this circulat ing water system .

Key words: board-ty peheat-exchanger, reasons for getting jammed, system adjustment