工业水处理 ›› 2014, Vol. 34 ›› Issue (12): 34-37. doi: 10.11894/1005-829x.2014.34(12).034

• 试验研究 • 上一篇    下一篇

纳滤膜处理含镍电镀废水的中试研究

宋卫锋, 汪卫, 唐铁柱, 倪俊, 武纯, 林丽婷   

  1. 广东工业大学环境科学与工程学院, 广东 广州 510006
  • 收稿日期:2014-11-03 出版日期:2014-12-20 发布日期:2015-01-14
  • 通讯作者: 汪卫, E-mail:775723118@qq.com E-mail:775723118@qq.com
  • 作者简介:宋卫锋(1972-), 副教授, 博士.电话:18929528006, E-mail:842663012@qq.com
  • 基金资助:

    广东省重大节能专项资助项目(122K0059)

Pilot scale study on nickel electroplating wastewater treatment by nano-filtration membrane

Song Weifeng, Wang Wei, Tang Tiezhu, Ni Jun, Wu Chun, Lin Liting   

  1. Faculty of Environment Science and Engineering, Guangdong University of Technology, Guangzhou 510006, China
  • Received:2014-11-03 Online:2014-12-20 Published:2015-01-14

摘要:

采用纳滤膜法对电镀镍漂洗废水及金属镍的在线回用进行中试研究,维持pH尧TDS尧电导率尧温度等条件不变,改变操作条件,研究了操作压力尧进水流量尧料液浓度尧运行时间尧产水比对膜分离性能的影响.研究结果表明,增加操作压力尧进水流量尧料液浓度都可提高Ni2+截留率及浓缩倍数;保持各影响因素恒定运行时,纳滤膜对Ni2+截留率及浓缩倍数随运行时间的延长逐渐增大,稳定运行40 h后接近最大截留率及最大浓缩倍数,截留率达75%左右,浓缩倍数在6.2 倍左右;产水比对Ni2+截留率有较大影响,产水比为1颐1尧进水流量为6 t/h 时,Ni2+截留率为65.7%,浓缩倍数为2.4 倍.

关键词: 纳滤膜, 电镀镍废水, 截留率, 浓缩倍数

Abstract:

The pilot scale study on the on-line reuse of nickel and nickel electroplating rinsing wastewater by nano- filtration membrane method has been conducted. When the pH,TDS,conductivity,temperature and other conditions remain unchanged,changing the operation conditions,the effects of pressure,influent flux,feed liquid concentration, operation time,and water production ratio on nano-filtration membrane separating capacity are studied. The results show that increasing operation pressure,influent flux and feed liquid concentration can raise the Ni2+ rejection rate and concentration multiple. With the influencing factors unchanged and under stable operation,by nano-filtration membrane,Ni2+ rejection rate and concentration multiple are gradually raised with the extension of operation time. After it runs stably for 40 h,the rejection rate and concentration multiple gets close to the maximum:rejection rate is about 75% and concentration multiple about 6.2 times. Water production ratio has greater impact on Ni2+ rejection rate. When water production ratio is 1:1,and influent flux is 6 t/h,the maximumrejection rate of Ni2+ is 65.7%,maximum concentration multiple is 2.4 times.

Key words: nano-filtration membrane, nickel electroplating wastewater, rejection rate, concentration multiple

中图分类号: