工业水处理 ›› 1998, Vol. 18 ›› Issue (6): 29-31,46. doi: 10.11894/1005-829x.1998.18(6).29

• 分析与监测 • 上一篇    下一篇

恒电量技术对冷却水腐蚀监测的研究

赵永韬, 赵常就, 陈范才   

  1. 湖南大学化学化工学院, 湖南长沙 410082
  • 收稿日期:1998-05-28 出版日期:1998-11-20 发布日期:2014-08-22
  • 作者简介:陈文闯, 1967年生, 1990年毕业于南开大学化学系,获硕士学位, 现就职于中石化总公司水处理技术服务中心,工程师。

A STUDY ON CORROSION MONITORING IN COOLING WATER BY COULOSTATIC METHOD

Zhao Yongtao   

  1. Dept. of Chem. of Hunan University, Changsha 410082
  • Received:1998-05-28 Online:1998-11-20 Published:2014-08-22

摘要:

运用恒电量技术对冷却水系统的腐蚀进行监测,通过Rp、Rf、Cf 等电化学参数的分析,能够随时报道水处理各阶段的腐蚀变化,尤其是能够灵敏地反映出预膜膜层生长情况。

关键词: 恒电量, 冷却水, 腐蚀监测

Abstract:

By acoulostatic pertur bation meter and a microcomputer as on-line measurem ent system, the cooling wate rsystems were mo nitored. Ba sed on the analysis of E-T attenuati on curves, relevant parameters, RpCd, Rf and Cf in equivalent circuit for the system, were obtained. Thus the corrosion of the systems could be reported at anytime, andin particular reflected sensitively was the situation of film forming at the stage of prefilming.

Key words: coulo static method, cooling water, corrosion monitoring