摘要:

用改进的硫化物吹气装置进行了温度、气速、时间等因素对回收率的影响试验,证明改进的硫化物吹气装置具有回收率高、省时、温度低等特点,新型硫化物吹气装置是成功的。

关键词: 硫化物, 吹气装置, 水质

Abstract:

Effect of the factors such as temperature,airflow and time on recovery ratio has been tested by using the improved blowing device. It shows the recovery ratio is high,the time is short and the temperature is low,proving the new device is successful.

Key words: sulfide, blowing device, water quality