INDUSTRIAL WATER TREATMENT ›› 2002, Vol. 22 ›› Issue (2): 40-43. doi: 10.11894/1005-829x.2002.22(2).40

Previous Articles     Next Articles

Development of the oil leakage alarm system and its application forcirculating water in refineries

LI Jie1, ZHANG Shenping1, YAN Lianhe2, ZHAO Xiaolei2   

  1. 1. Shengli Refinery of Petrochemical Corporation, Zibo 255434,China;
    2. Water Treatment Institute,Nanjing University of Science and Technology, Nanjing 210094,China
  • Received:2001-07-16 Online:2002-02-20 Published:2010-10-01

炼油厂循环水漏油报警器的开发及应用

李杰1, 张慎平1, 严莲荷2, 赵晓蕾2   

  1. 1. 齐鲁石化公司胜利炼油厂, 山东淄博 255434;
    2. 南京理工大学水处理研究所, 江苏南京 210094
  • 作者简介:李杰(1971-),1994年毕业于石油大学化机专业,助理工程师。

Abstract:

An oil leakage detecting and alarming inst rument used in circulating water system has been developed,based on determining the oil-in-water content by turbidimet ry.The inst rument can control a number of point s.Thus the oil-leaking si tuation in the water can be detected in t ime, finding out the point of leakage.The quicklyand accurately applicat ion in si tu indicates that the instrument is fast, responsive and easy to operate w ith highprecisio n.

Key words: oilleakage alarm instrument, circulating water, principle, application

摘要:

利用浊度法测定水中的油含量,研制了一种用于循环水系统的漏油报警器。该报警器可进行多点控制,及时发现水中的漏油情况,迅速查出漏油点。通过现场的实际应用,证明该报警器快捷、简便、准确度高。

关键词: 漏油报警器, 循环水, 原理, 应用;

CLC Number: