INDUSTRIAL WATER TREATMENT ›› 2003, Vol. 23 ›› Issue (3): 23-25. doi: 10.11894/1005-829x.2002.23(3).23

Previous Articles     Next Articles

STUDIES ON THE APPLICATION OF CATIONIC FLOCCULANT PDA TO TREATMENT OF DYEING WASTEWATER

Zhang Yuejun, Xing Yunjie, Liu Ying, Wang Jing, Zhang Jinhua   

  1. School of Chemical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
  • Received:2002-09-15 Online:2003-03-20 Published:2010-10-01

阳离子絮凝剂PDA用于印染废水处理的研究

张跃军, 邢云杰, 刘瑛, 王晶, 张晋华   

  1. 南京理工大学化工学院, 江苏南京 210094
  • 作者简介:张跃军(1959- ), 1989 年毕业于华东工学院, 博士学位, 现为南京理工大学化工学院副院长, 教授。

Abstract:

The treatment process of dyeing wastewater by using cationic flocculant PDA is reported. The results show that when cationic flocculant PDA is used with inorganic flocculant PAC to treat the dyeing wastewater that has been biochemically treated and that hasn't been biochemically treated, the CODCr removal rate is 31% and 55% respectively; the chromaticity goes down to 16 times from as high as 130 times and 57 times respectively;and the permeable ratio of upper clean liquid are 89.4% and 89.9% respectively. By comparison,the results obtained by using PDA are as good as or superior to that by using other commercial cationic flocculants.

Key words: cationic flocculant, dyeing wastewater , dimethyldiallylammonium

摘要:

报道了用阳离子絮凝剂PDA对一种活性和分散染料的混合印染废水处理的研究过程。结果表明, 用阳离子絮凝剂PDA与无机絮凝剂PAC配合使用处理未经生化处理和经生化处理的印染废水, 其CODCr去除率分别为31%和55%;色度分别从130倍和57倍降低到16倍;上清液透过率分别为89.4%和89.9%。其CODCr去除率、脱色率和上清液透过率均相同或超过其他作对比的阳离子絮凝剂。

关键词: 阳离子絮凝剂, 印染废水, 二甲基二烯丙基氯化铵

CLC Number: