Abstract:
Some design factors, which should be taken into account in the process design of reverse osmosis system for treating surface water have been described. It is based on the projects, such as Ningxia Shizui Mountain Power Plant Project to treat Yellow River water and Hebei Dingzhou Power Plant project to treat reservoir water, etc., which have been designed in recent years. It deals with different conditions during the application of these projects and some relative references.
Key words:
surface water treatment,
reverse osmosis,
process design
摘要:
参照作者近几年来设计的几套反渗透处理地表水的项目(如宁夏石嘴山电厂反渗透以黄河水为水源、河北定州电厂以水库水为水源等)在调试过程中遇到的不同情况,简要介绍了采用反渗透工艺处理地表水系统设计过程中需要考虑的设计因素。
关键词:
地表水处理,
反渗透,
工艺设计
CLC Number:
Wang Lilin. Process design of reverse osmosis system for treating surface water[J]. INDUSTRIAL WATER TREATMENT, 2005, 25(7): 72-73.
王利林. 反渗透系统处理地表水的工艺设计[J]. 工业水处理, 2005, 25(7): 72-73.