INDUSTRIAL WATER TREATMENT ›› 2006, Vol. 26 ›› Issue (5): 44-46. doi: 10.11894/1005-829x.2006年.26(05).44

Previous Articles     Next Articles

Research on applying MBR to treat the acid pickling wastewater for boilers in the power plant

Zhang Ping1, Chen Xiaoyu2, Song Liqun3, Shen Baozhong3   

  1. 1. Shanghai University of Electric Engineering, Shanghai 200090, China;
    2. Yangshupu Electric Power Plant, Shanghai 200090, China;
    3. Huaneng Shidongkou 2nd Electric Power Plant, Shanghai 200942, China
  • Received:2006-01-17 Revised:2006-01-17 Online:2006-05-20 Published:2010-10-01

应用MBR处理电厂锅炉酸洗废水的研究

张萍1, 陈晓宇2, 宋立群3, 沈保中3   

  1. 1. 上海电力学院, 上海 200090;
    2. 上海杨树浦电厂, 上海 200090;
    3. 华能石洞口二厂, 上海 200942
  • 作者简介:张萍(1960- ),1982 年毕业于华东理工大学化学工程 专业。上海电力学院讲师。电话: 021- 65430410- 299,E- mail: junnyp@online.sh.cn。

Abstract:

In order to remove CODCr and meet drainage criterion of the wastewater, the membrane bioreactor is used for treating the acid pickling wastewater for boilers in the power plant. The best operation conditions are proved in this experiment: 8 h of the hydraulic retention time, DO about 2 mg/L, pH6-8, temperature 20 ℃, mixed-liquor suspended solid 1 g/L, settled volume ofsludge 10%,12 h continuingfeed-in and continuingforcingair. CODremoval efficiency is about 88.50% and TOC removal rate is about 85.60%.

Key words: membrane bio-reactor, acid pickling wastewater for boilers, removal efficiency of TOC

摘要:

应用膜生物反应器处理锅炉酸洗废水可以达到减低CODCr并使之达标排放的目的。其最佳的操作条件是停留时间8h,12h连续进料,闲置12h,进料时12h连续曝气,pH在6~8,水温20℃,DO为2mg/L左右,污泥质量浓度约为1g/L,污泥沉降比为10%。CODCr去除率为88.50%左右,TOC去除率为85.60%左右。

关键词: 膜生物反应器, 锅炉酸洗废水, TOC去除率

CLC Number: