INDUSTRIAL WATER TREATMENT ›› 2008, Vol. 28 ›› Issue (7): 74-77. doi: 10.11894/1005-829x.2008.28(7).74

Previous Articles     Next Articles

The application of turbidimetry to the determination of micro solid granulaconcentration in suspension

Meng Qinggong1,2, Tang Xiaojin2, Lü Lufeng2, Zhang Zhanzhu2   

  1. 1. Hubei Chemical Fertilizer Co., SINOPEC, Zhijiang 443200, China;
    2. Research Institute of Petroleum Processing, Beijing 100083, China
  • Received:2008-03-30 Online:2008-07-20 Published:2010-10-01

浊度法用于测量悬浮液中微量固体颗粒浓度

孟庆功1,2, 唐晓津2, 吕庐峰2, 张占柱2   

  1. 1. 中国石油化工股份有限公司湖北化肥分公司, 湖北枝江 443200;
    2. 石油化工科学研究院, 北京 100083
  • 作者简介:杨继东(1980-),2006年毕业于吉林大学,硕士,助理工程师.电话:022-26689123,E-mail:yangjidong2000@126.com.

Abstract:

Since the suspension contains microfine molecular sieve and nickel respectively, the turbidimetry has been applied to the determination of the micro solid granula in the suspension. The effects of correlative factors have been studied. The results indicate that the concentration and turbidity of the microfine suspension have linear correlation within the test range. To the microfine granule suspension, d32(Sauter diameter) is recommended for reflecting better effect of granule factor on the turbidity than that of using d50(median diameter).

Key words: suspension, turbidity, average diameter ofgranula

摘要:

采用浊度法检测含有微量细小的分子筛颗粒和金属镍颗粒的悬浮液中微量固体颗粒浓度,并对相关因素的影响进行了研究。结果表明:在实验范围内,悬浮液微细颗粒的浓度与悬浮液浊度成线性关系;对微细颗粒悬浮液,采用d32(Sauter直径)作为平均直径比采用中位直径d50更能反应出粒径因素对浊度的影响。

关键词: 悬浮液, 浊度, 颗粒平均直径

CLC Number: