INDUSTRIAL WATER TREATMENT ›› 2010, Vol. 30 ›› Issue (10): 84-85. doi: 10.11894/1005-829x.2010.30(10).84

Previous Articles     Next Articles

The engineering example of dyeing wastewater treatment with hydrolytic acidfication and bio-contact oxidation

Liu Haicheng1, Chang Zhanghong2, Wang Xianli1, Wu Junfeng1   

  1. 1. Henan University of Urban Construction, Department of Environmental and Muncipal Engineering, Pingdingshan 467044, China;
    2. Xj Lianhua Int’l Environmental Co, Ltd, Zhengzhou 450004, China
  • Received:2010-05-05 Revised:2010-05-05 Online:2010-10-20 Published:2010-10-01

水解酸化/生物接触氧化工艺处理印染废水应用实例

刘海成1, 常张红2, 王现丽1, 吴俊峰1   

  1. 1. 河南城建学院, 河南 平顶山 467044;
    2. 许继联华郑州分公司, 河南 郑州 450004
  • 作者简介:刘海成(1973- ),2007年毕业于华中科技大学环境科学与工程学院,硕士,讲师,研究方向:污水处理理论与技术.电话:13949499773,E- mail:liuhc88@hnj.edu.cn

Abstract:

The design and performance for dyeing wastewater treatment with hydrolytic acidification and bio-contact oxidation are discussed.The performance indicates that the removals of COD,BOD,SS and chroma can reach 95.8%,95.3%,92.4%,and 96.2% respectively,when the influent concentrations of COD,BOD,SS and chroma are 1 025,343,421 mg/L and 500 times.And the effluent concentrations of COD,BOD,SS and chroma are 43,16,32 mg/L and 19 times,respectively.The water quanlity of effluent is stable and the effluent can achieve first class of Integrated Wastewater Discharge Standard(GB 8978—1996).

Key words: hydrolytic acidification, bio-contact oxidation, dyeing wastewater

摘要:

介绍了采用水解酸化/生物接触氧化工艺处理印染废水的应用实例。运行结果表明,该工艺能有效去除废水中的污染物,当进水CODCr为1025mg/L、BOD5为343mg/L、SS为421mg/L、色度为500倍时,处理后出水CODCr、BOD5、SS分别可达到43、16、32mg/L,色度可降低到19倍,去除率分别为95.8%、95.3%、92.4%、96.2%。经该工艺处理后的出水水质稳定,并达到了《污水综合排放标准》(GB8978—1996)一级标准。

关键词: 水解酸化, 生物接触氧化, 印染废水, 应用实例