Abstract:
Fe/C micro-electrolysis-photocatalysis process has been used for pretreating electroplating wastewater which contains great quantity of Cu2+ and organic matter.The experimental results show that the appropriate parameters of the pretreatment are as follows:the Fe/C micro-electrolysis takes the removal of Cu2+ as its indicator by carrying on the orthogonal text.Its initial pH of wastewater is 3,Fe/C mass ratio 1∶1,dosage of iron 60 g/L,reaction time 60 min.The photocatalysis takes the removal of organic matter as its indicator by single-factor test,and nano-TiO2 solution colloid as catalyst.Its pH is 3,the dosage of TiO2 40 mL/L,time of UV irradiation 60 min.The removal rates of Cu2+ removing rate in the effluent water flocculated,after the wastewater is pretreated,reaches 99.98% and COD removing rate is above 60%.
Key words:
electroplating wastewater,
micro-electrolysis,
photocatalysis
摘要:
利用Fe/C微电解-光催化法对含有大量Cu2+和有机物的电镀废水预处理。实验结果表明,预处理的适宜参数为:Fe/C微电解法以除Cu2+为指标进行正交实验,废水初始pH=3,Fe/C=1∶1,铁投加质量浓度为60 g/L,反应时间为60 min;光催化法以除有机物为指标进行单因素实验,采用纳米TiO2溶胶为催化剂,pH=3,TiO2加入量为40mL/L,紫外光照时间60 min。电镀废水经预处理后再絮凝处理,出水Cu2+去除率为99.98%,COD去除率>60%。
关键词:
电镀废水,
微电解,
光催化
CLC Number:
Peng Renyong,Cheng Baozhen,Zhang Ligang. Pretreatment of electroplating wastewater by Fe/C micro-electrolysis一photocatalysis process[J]. INDUSTRIAL WATER TREATMENT, 2011, 31(12): 67-69.
彭人勇,程宝珍,张利刚. Fe/C微电解-光催化联合预处理电镀废水的研究[J]. 工业水处理, 2011, 31(12): 67-69.