INDUSTRIAL WATER TREATMENT ›› 2011, Vol. 31 ›› Issue (2): 79-81,92. doi: 10.11894/1005-829x.2011.31(2).79

Previous Articles     Next Articles

Optimization of the filling of ion exchanger resin

Mao Guoqun1, Gao Lihua2, Yang Wanwan1, Yang Jun3   

  1. 1. Beijing Yanshan Petrochemical Co. , Ltd. , Beijing 102500, China;
    2. Department of Environmental Engineering, North China Institute of Science and Technology, Sanhe 065201, China;
    3. School of Chemical Engineering, Sichuan University, Chengdu 610065, China
  • Revised:2010-10-17 Online:2011-02-20 Published:2011-03-02

离子交换器树脂的填装优化

毛国群1, 高丽花2, 杨万万1, 杨军3   

  1. 1. 北京燕山石油化工有限公司, 北京 102500;
    2. 华北科技学院环境工程系, 河北三河 065201;
    3. 四川大学化工学院, 四川成都 610065
  • 作者简介:周军1976,2005年毕业于同济大学硕士,讲师,电话13639903762,Email:jzizjp@zzuli.edu.cn

Abstract:

The effect of water quality changes on the desalting system of chemical water treatment at Beijing Yanshan Petrochemical Co.,Ltd.is discussed.Based on the new production conditions,the ion exchanger resin filling is optimized and through tests on site and industrial application,the periodic water production has been increased by 15%,and CNY 186 000 can be save annually for the running cost.As a result,good effect and economic benefit have been gained.

Key words: ion exchanger, desalination, exchange capacity

摘要:

论述了水质改变对北京燕山石油化工有限公司化学水处理装置除盐系统的影响。根据变化后的生产条件,优化了离子交换器树脂的装填比例。现场试验及工业化应用结果表明,优化后周期制水量提高15%,年运行费用节约18.6万元,取得了良好的效果与经济效益。

关键词: 离子交换器, 脱盐, 工作交换容量