Urban landfill leachate treatment by microelectrolysis-UASB

Yu Xin1, Lin Geng2   

  1. 1. Environmental Engineering Department, University of Science and Technology Beijing, Beijing 100083, China;
    2. General Construction Research Institute of Metallurgical Corporation of China, Beijing 100088, China
  • Received:2010-11-17 Online:2011-03-20 Published:2011-03-22

微电解—UASB组合工艺处理城市垃圾渗滤液

于昕1, 林庚2   

  1. 1. 北京科技大学环境工程系, 北京 100083;
    2. 中冶集团建筑研究总院, 北京 100088
  • 作者简介:于昕(1979- ), 2008 年毕业于北京科技大学, 博士, 现为北京科技大学在站博士后, 主要研究方向为环境水处理。电话:13261820380, E-mail: rollyu@126.com。
  • 基金资助:

    “十一五”国家科技支撑计划重点项目(2007BAC16B03);国家科技支撑计划课题(2006BAC06B01)

Abstract:

The treatment of landfill leachate by microelectrolysis-UASB has been studied. The results show that microelectrolysis is a good and cheap pretreatment process, 56.3% of CODCr could be removed from landfill leachate, and B/C is improved from raw water 0.28 to 0.35. UASB could treat the effluent effectively after treated by microelectrolysis process, the CODCr removal rate is more than 73%. The combined microelectrolysis-UASB process could remove most of the CODCr from landfill leachate and improve its biodegradability.

Key words: microelectrolysis, upflow anaerobic sludge bed, landfill leachate

摘要:

研究了微电解和上流式厌氧污泥床(UASB)组合工艺处理城市垃圾渗滤液的效果。结果表明:微电解是一种理想的垃圾渗滤液预处理方法, 其CODCr去除率可达到56.3%, B/C由原水的0.28上升到0.35;UASB能够有效地处理微电解处理后的出水, CODCr去除率能达73%以上。微电解和UASB组合工艺能去除城市垃圾渗滤液中的大部分CODCr, 并提高其可生化性。

关键词: 微电解, 上流式厌氧污泥床, 垃圾渗滤液