INDUSTRIAL WATER TREATMENT ›› 2017, Vol. 37 ›› Issue (11): 58-61. doi: 10.11894/1005-829x.2017.37(11).058

Previous Articles     Next Articles

Research on the electric flocculation treatment of shale gas fracturing flow back fluid

Meng Xuanyu1, Zhu Yingli1, Lin Wenjie1, Guo Chunmei1,2, Kong Fanxin1,2, Chen Jinfu1,2   

  1. 1. China University of Petroleum, Beijing 102249, China;
    2. Beijing Key Laboratory of Oil & Gas Pollution Control, Beijing 102249, China
  • Received:2017-09-09 Online:2017-11-20 Published:2017-12-21

页岩气压裂返排液电絮凝处理技术研究

孟宣宇1, 朱营莉1, 林雯杰1, 郭春梅1,2, 孔繁鑫1,2, 陈进富1,2   

  1. 1. 中国石油大学(北京), 北京 102249;
    2. 油气污染防治北京市重点实验室, 北京 102249
  • 通讯作者: 陈进富,博士,教授。
  • 作者简介:孟宣宇(1992-),在读研究生。电话:18519892664。
  • 基金资助:
    重庆市国土资源和房屋管理局科技计划项目(CQGT-KJ-2012-6)

Abstract: The electric flocculation technology has been used for treating the shale gas fracturing flow back fluid, and the treatment effects of operating conditions on shale gas fracturing flow back fluid investigated. The optimal experimental conditions of electric flocculation technology are determined as follows:aluminum plates are selected as the cathode and anode materials,the current density is 10.0 mA/cm2,plate spacing 3 cm,reaction time 60 min,and pH=7. The experimental results show that the electric flocculation technology has good treatment effects on low concentration shale gas fracturing flow back fluid. It is expected to be an important unit of standard discharge combined process of shale gas fracturing flow back fluid.

Key words: electric flocculation, fracturing flow back fluid, current density

摘要: 采用电絮凝技术对页岩气压裂返排液进行处理,考察了各操作条件对页岩气压裂返排液处理效果的影响,确定了电絮凝处理的最佳实验条件:阴阳极材料均为铝板,电流密度10.0 mA/cm2,极板间距3 cm,反应时间60 min,pH=7。电絮凝工艺对低浓度页岩气压裂返排液具有较良好的处理效果,可望成为页岩气压裂返排液达标排放组合工艺的重要单元。

关键词: 电絮凝, 压裂返排液, 电流密度