Industrial Water Treatment ›› 2019, Vol. 39 ›› Issue (12): 107-109. doi: 10.11894/iwt.2018-1164

• Exchanges of Experiences • Previous Articles     Next Articles

Technical application and research of UF and RO membranes in chemical wastewater treatment and reuse

Yanjun Liu(),Yan Zhou   

  1. Wuhan Kaidi Water Service Co., Ltd., Wuhan 430074, China
  • Received:2019-11-07 Online:2019-12-20 Published:2019-12-21

双膜法处理化工废水及回用工程应用研究

刘艳军(),周艳   

  1. 武汉凯迪水务有限公司, 湖北武汉 430074
  • 作者简介:刘艳军(1973-),工程师。电话:13971316621, E-mail:13971316621@139.com

Abstract:

Ultrafiltration(UF) and reverse osmosis(RO) membrane technologies are applied in the chemical wastewater treatment and reuse in a chemical manufacturing group. The results show that the comprehensive treatment system has excellent removal of pollutants. The removal rate of the conductivity can reach as high as 98%. The quality and quantity of the production water are stable and can meet the requirements of the chemical process. The successful operation of the system achieves the near-zero-emission of wastewater.

Key words: chemical wastewater, ultrafiltration, reverse osmosis, reuse

摘要:

采用超滤膜及反渗透膜工艺处理某化工集团产生的化工废水并回用。结果表明,系统对污染物去除效果较好,电导率去除率可稳定在98%以上。系统产水水质、水量稳定,产水可回用于化工生产工艺,满足化工工艺要求,实现了生产废水"近零排放"的目标。

关键词: 化工废水, 超滤, 反渗透, 回用

CLC Number: