Industrial Water Treatment ›› 2021, Vol. 41 ›› Issue (7): 112-116. doi: 10.19965/j.cnki.iwt.2020-0937

• Research and Experiment • Previous Articles     Next Articles

Optimization of NaHSO3 enhanced Fe2+/persulfate system for treatment of eriochrome black T wastewater by response surface methods

Shuai An(),Haisong Li*()   

  1. College of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, China
  • Received:2021-05-12 Online:2021-07-20 Published:2021-07-26
  • Contact: Haisong Li E-mail:245209953@qq.com;lhs@zzu.edu.cn

NaHSO3强化Fe2+/过硫酸盐体系处理铬黑T废水的优化

安帅(),李海松*()   

  1. 郑州大学生态与环境学院, 河南郑州 450001
  • 通讯作者: 李海松 E-mail:245209953@qq.com;lhs@zzu.edu.cn
  • 作者简介:安帅(1995-), 硕士。E-mail: 245209953@qq.com

Abstract:

Eriochrome black T(EBT) was degraded by strengthening Fe2+/persulfate(PS) system with sodium bisulfite(NaHSO3). Based on single factor experimental results, Fe2+ concentration, NaHSO3 dosage and PS concentration were selected as the investigation factors, and EBT removal rate was taken as response value, a quadratic mathematical model was established by Box-Behnken response surface method to analyze the influence of various factors and their interactions on EBT degradation. The optimal condition were Fe2+ 0.08 mmol/L, NaHSO3 dosage 0.90 mmol/L and PS 1.00 mmol/L respectively, and the predicted EBT removal rate was 93.7%. The average result of verification test was 92.76%, which had a deviation of 0.94% compared with the predicted value.

Key words: sodium bisulfite, persulfate, eriochrome black T, response surface methodology

摘要:

采用亚硫酸氢钠(NaHSO3)强化Fe2+/过硫酸盐(PS)体系降解铬黑T(EBT)。基于单因素实验结果,以Fe2+浓度、NaHSO3投加量和PS浓度作为考察因素,EBT去除率为响应值,采用Box-Behnken响应曲面法建立二次数学模型,分析各因素及其交互作用对EBT降解的影响。在模型优化条件,即Fe2+浓度0.08 mmol/L、NaHSO3投加量0.90mmol/L、PS浓度1.00 mmol/L条件下,预测EBT去除率为93.7%。验证实验平均结果为92.76%,与预测值偏差为0.94%。

关键词: 亚硫酸氢钠, 过硫酸盐, 铬黑T, 响应曲面法

CLC Number: