Abstract:
The reconstruction of dyeing-weaving wastewater treatment in a dyeing-weaving plant is presented. The dyeing-weaving wastewater has been treated with the process of hydrolytic acidification-contact oxidation-coagulation and air floatation. The running results have shown that when the inlet CODCr、BOD5 and SS are in the range of 900 - 1100 mg/L, 250 - 350 mg/L and 350 - 450 mg/L respectively, the effluent of the system is good enough to meet the first grade of national wastewater integrated discharge standard (GB 8978—1996).
Key words:
dyeing-weaving wastewater,
hydrolytic acidification,
contact oxidation,
coagulation and air floatation
摘要:
介绍了某染织厂废水处理设施的改造工程。采用水解酸化、接触氧化、混凝气浮工艺处理染织废水, 取得了良好的处理效果。运行结果表明, 在进水CODCr、BOD5、SS分别为900~1 100、250~350、350~450 mg/L的条件下, 出水达到GB 8978—1996一级排放标准。
关键词:
染织废水,
水解酸化,
接触氧化,
混凝气浮
CLC Number:
Gao Tingdong. Des ign and debugging of the recons truction of dyeing-weaving was tewater treatment[J]. INDUSTRIAL WATER TREATMENT, 2007, 27(11): 85-88.
高廷东. 染织废水处理改造工程设计及调试运行[J]. 工业水处理, 2007, 27(11): 85-88.