INDUSTRIAL WATER TREATMENT ›› 2012, Vol. 32 ›› Issue (11): 24-27. doi: 10.11894/1005-829x.2012.32(11).24

Previous Articles     Next Articles

Experiment research on the pretreatment of acrylic fiber wastewater by three-dimentional electrode technology

Wang Ya'e1, Li Jie1, Zhen Xiaohua1, Zhou Yuexi2, Jiang Jinyuan2   

  1. 1. School of Environmental and Municipal Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China;
    2. Department of Water Pollution Control Technology, Chinese Research Academy of Environmental Sciences, Beijing 100044, China
  • Received:2012-07-30 Online:2012-11-20 Published:2012-11-29

三维电极技术预处理腈纶废水的试验研究

王亚娥1, 李杰1, 甄晓华1, 周岳溪2, 蒋进元2   

  1. 1. 兰州交通大学环境与市政工程学院, 甘肃 兰州 730070;
    2. 中国环境科学研究院水污染控制技术研究室, 北京 100044
  • 作者简介:王亚娥(1963- ), 研究生导师, 副教授联系人:甄晓华, 电话:18647727559, E-mail:zhenxh0260@163.com
  • 基金资助:

    国家水体污染控制与治理科技重大专项(2012ZX07201-005)

Abstract:

The three-dimentional electrode technique has been used for treating acrylic fiber wastewater. Through single factor and orthogonal experiment,the effects of electrolytic voltage,reaction time and pH on COD removing rate of the wastewater and energy consumption are investigated. The results show that the COD removing rate reaches around 29% and the biodegradability of the wastewater is raised from 0.28 to 0.41 and the energy consumption is around 1.33 kW·h/t,when the voltage is 20 V,electrolysis time 60 min,and pH=5.0.

Key words: three-dimentional electrode, acrylic fiber wastewater, electrochemical method

摘要:

采用三维电极技术处理难降解腈纶废水,通过单因素及正交试验考察了电解电压、反应时间以及pH对废水COD去除率和反应能耗的影响。试验结果表明,在电压为20 V,电解时间为60 min,pH为5.0的条件下,三维电极对腈纶废水的COD去除率达到29%左右,废水的可生化性由0.28提高到0.41,处理每吨废水能耗为1.33 kW.h左右。

关键词: 三维电极, 腈纶废水, 电化学法

CLC Number: