INDUSTRIAL WATER TREATMENT ›› 2012, Vol. 32 ›› Issue (4): 85-87. doi: 10.11894/1005-829x.2012.32(04).85

Previous Articles     Next Articles

Optimized experiments on the boiler-water treatment method of 600 MW sub-critical boiler unit

Xing Chengxia, Wang Yinggao, Li Yongli, Jin Xuliang, Zhou Zilong   

  1. North China Electric Power Research Institute, Beijing 100045, China
  • Received:2012-02-14 Online:2012-04-20 Published:2012-04-13

600MW亚临界汽包炉炉水处理工艺优化试验

星成霞, 王应高, 李永立, 金绪良, 周子龙   

  1. 华北电力科学研究院有限责任公司, 北京 100045
  • 作者简介:星成霞(1976- ),2004 年毕业于东北电力学院,硕士, 工程师, 主要从事电厂化学监督工作。电话:13681261219,E-mail:xingchengxia@126.com。

Abstract:

The boiler-water treatment method of 600 MW sub-critical boiler unit has direct influence on its steam quality. It is important to optimize the boiler-water treatment method in order to improve boiler steam quality and prevent salt deposits on steam turbine. Based on experiments, the effect of phosphate concentration in the boiler water of several 600 MW sub-critical boilers of the same type on steam quality has been investigated quantitatively. The optimal boiler-water treatment process of every unit and corresponding boiler-water quality controlling scheme are determined.

Key words: 600 MW sub-critical boiler unit, low-concentration phosphate treatment (LPT), equilibrium-concentration phosphate treatment (EPT), sodium ion content in steam.

摘要:

600 MW亚临界汽包炉炉水的处理方式影响机组的蒸汽品质,优化炉水处理工艺对于提高锅炉蒸汽品质、预防汽轮机积盐具有重要作用。通过试验定量考察了数台同型号600 MW亚临界汽包炉炉水磷酸盐含量对蒸汽品质的影响,确定了各机组最优的炉水处理工艺及炉水水质监控指标最优控制方案。

关键词: 600MW亚临界汽包炉, 低磷酸盐处理, 平衡磷酸盐处理, 蒸汽钠含量

CLC Number: