Industrial Water Treatment ›› 2020, Vol. 40 ›› Issue (4): 39-43. doi: 10.11894/iwt.2019-0455

• Research and Experiment • Previous Articles     Next Articles

The treatment of folic acid wastewater by photoelectric synergistic treatment with activated carbon particle loaded with Fe-TiO2

Junwo Zhou(),Yong Gao,Zhen Zhou,Tingting Li,Chu Sun,Yuxuan Liu,Rong Mei   

  1. School of Chemical & Environmental Engineering, Jiangsu University of Technology, Changzhou 213001, China
  • Received:2020-01-04 Online:2020-04-20 Published:2020-04-21

活性炭颗粒负载Fe-TiO2光电协同处理叶酸废水

周俊我(),高永,周桢,李婷婷,孙楚,刘宇轩,梅蓉   

  1. 江苏理工学院化学与环境工程学院, 江苏常州 213001
  • 作者简介:周俊我(1995-),硕士研究生。电话:13775185565, E-mail:13775185565@163.com
  • 基金资助:
    国家自然科学基金青年基金(51508239);江苏省产学研前瞻性联合研究项目(BY2016030-26)

Abstract:

Folic acid wastewater is treated by three-dimensional electrode coupling photocatalysis. A Fe-doped TiO2supported activated carbon particle electrode Fe-TiO2/AC is prepared by sol-gel method, and then characterized by XRD, SEM and BET. The operating parameters of three-dimensional electrode coupling photocatalysis are optimized for the folic acid wastewater treatment. The results show that Fe-TiO2/AC has better morphology and photocatalytic activity than TiO2/AC. Under the following conditions:doping amount in Fe of 0.4%, the current density of 0.6 mA/cm2, pH of 5, and aeration of 6 L/min, the TOC removal reaches 82.4% after 120 minutes of reaction. The reaction confirms to the second-order kinetic model and has obvious photoelectric synergistic enhancement effect in the degradation process of organic matter.

Key words: iron doping, titanium dioxide, photocatalysis, three-dimensional electrolysis, folic acid wastewater

摘要:

采用三维电极耦合光催化处理叶酸废水。通过溶胶-凝胶浸渍法制备了掺Fe改性TiO2负载活性炭颗粒电极(Fe-TiO2/AC),进行XRD、SEM和BET表征,并优化三维电极耦合光催化处理叶酸废水的运行参数。结果表明,Fe-TiO2/AC比TiO2/AC有更好的形貌结构和光催化活性。在Fe掺杂质量分数为0.4%,电流密度为0.6 mA/cm2,pH为5,曝气量为6 L/min的条件下,反应120 min后TOC去除率达到82.4%。反应符合二级动力学模型,在有机物降解过程中具有明显的光电协同增强作用。

关键词: Fe掺杂, 二氧化钛, 光催化, 三维电解, 叶酸废水

CLC Number: