工业水处理 ›› 2020, Vol. 40 ›› Issue (2): 28-31. doi: 10.11894/iwt.2019-0295

• 试验研究 • 上一篇    下一篇

铁碳微电解耦合人工湿地系统处理硫丹废水研究

田开放1(),张漓杉1,*(),张静1,钟山1,刘俊勇1,2,谢沅汕1,2,高品3   

  1. 1. 广西师范大学环境与资源学院, 广西桂林 541004
    2. 珍稀濒危动植物生态与环境保护教育部重点实验室, 广西桂林 541006
    3. 东华大学环境科学与工程学院, 上海 201620
  • 收稿日期:2019-05-13 出版日期:2020-02-20 发布日期:2020-02-22
  • 通讯作者: 张漓杉 E-mail:985601258@qq.com;lishan.z@qq.com
  • 作者简介:田开放(1992-),硕士在读。E-mail:985601258@qq.com
  • 基金资助:
    国家自然科学基金资助项目(51469006);广西科技攻关计划项目(桂科攻1598016-4);桂林市科技计划项目(2016012506)

Study on the treatment of endosulfan wastewater by iron-carbon micro-electrolysis coupled constructed wetland system

Kaifang Tian1(),Lishan Zhang1,*(),Jing Zhang1,Shan Zhong1,Junyong Liu1,2,Yuanshan Xie1,2,Pin Gao3   

  1. 1. College of Environment and Resources, Guangxi Normal University, Guilin 541004, China
    2. Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection(Guangxi Normal University), Ministry of Education, Guilin 541004, China
    3. College of Environmental Science and Engineering, Donghua University, Shanghai 201620, China
  • Received:2019-05-13 Online:2020-02-20 Published:2020-02-22
  • Contact: Lishan Zhang E-mail:985601258@qq.com;lishan.z@qq.com
  • Supported by:
    国家自然科学基金资助项目(51469006);广西科技攻关计划项目(桂科攻1598016-4);桂林市科技计划项目(2016012506)

摘要:

研究构建了2个人工湿地系统,系统A为传统人工湿地系统,系统B中添加有铁碳填料,即为铁碳微电解耦合人工湿地系统,对比了2个系统对不同浓度硫丹废水的处理效果。结果显示,系统B对废水中硫丹的总去除率可达86.9%~98.0%,对COD、磷酸盐和氨氮的去除率分别为78.7%~84.3%、86.7%~94.2%和75.9%~83.3%,处理效果优于系统A。硫丹对湿地系统中的基质酶活性有抑制作用,但系统B中的脲酶、脱氢酶以及3种磷酸酶的活性均高于系统A,表明铁碳微电解耦合人工湿地系统能够有效适应高浓度硫丹的冲击。

关键词: 铁碳微电解, 人工湿地, 硫丹, 酶活性

Abstract:

Two constructed wetlands systems were established. System A was a traditional constructed wetland system. System B contained iron-carbon filler, which was an iron-carbon micro-electrolysis coupled constructed wetland system. The treatment effects of two systems on different concentrations of endosulfan wastewater were compared. The results showed that the total removal rate of endosulfan in wastewater from system B was 86.9%-98.0%, and the removal rates of COD, phosphate and ammonia nitrogen were 78.7%-84.3%, 86.7%-94.2% and 75.9%-83.3%, respectively, the processing effect was better than system A. Endosulfan inhibited the activity of matrix enzymes in the wetland system, but the activities of urease, dehydrogenase and three phosphatases in system B were higher than those in system A, indicating that the iron-carbon micro-electrolysis coupled constructed wetland system could effectively adapt to the impact of high concentrations of endosulfan.

Key words: iron-carbon micro-electrolysis, constructed wetlands, endosulfan, enzymatic activity

中图分类号: