摘要:
研究了利用直接电导检测-离子色谱法分离测定电厂水汽中Na+、NH4+、K+、Ca2+、Mg+5种阳离子的方法。选择色谱条件为Ion Pac CS12A阳离子交换柱,20 mmol/L甲基磺酸淋洗液,抑制性电导检测。该方法采用500μL进样,5种阳离子的检出限为0.03~0.13μg/L,相对标准偏差(RSD,n=5)在0.24%~2.5%之间,加标回收率为96%~110%,该方法具有选择性好、检出限低、灵敏度高、操作简便等特点,可用于电厂给水、凝结水、蒸汽等水样中阳离子的测定。
关键词:
离子色谱,
电厂,
锅炉水,
阳离子
Abstract:
The method by using direct conductivity detection-ion chromatography process for separating and determining five kinds of cations:Na+,NH4+,K+,Ca2+,Mg2+ has been studied. The chromatographic condtions are Ion Pac CS12A cationic exchange column,20 mmol/L methanesulfonic acid leacheate and inhibiting electric-conductance detection. The sample used is 500 μL. Detection limit of the 5 kinds of cations is 0.03-0.13 μg/L,and relative standard deviations(RSD,n=5) 0.24%-2.5%,and the standard recoveries 96%-110%. This method is characterized by good selectivity,low detection limit,high sensitivity,easy operation,etc. It can be used for determining cations in samples,such as water supply in power plants,condensed water,steam,etc.
Key words:
ion chromatography,
power plant,
boiler water,
cations
中图分类号:
李瑛, 黄万启, 常旭红, 曹松彦, 王海莲. 离子色谱法测定电厂锅炉水汽中痕量阳离子[J]. 工业水处理, 2012, 32(11): 84-86.
Li Ying, Huang Wanqi, Chang Xuhong, Cao Songyan, Wang Hailian. Study on the determination of trace cations in the boiler vapor of power plants by ion chromatography[J]. INDUSTRIAL WATER TREATMENT, 2012, 32(11): 84-86.