工业水处理 ›› 2004, Vol. 24 ›› Issue (9): 74-76. doi: 10.11894/1005-829x.2004.24(9).74

• 经验交流 • 上一篇    下一篇

低压加热器铜合金腐蚀原因分析及对策

贾宁1, 富丽娟2   

  1. 1. 南京热电厂, 江苏南京 210035;
    2. 东北电力学院, 吉林市 132012
  • 收稿日期:2004-05-17 出版日期:2004-09-20 发布日期:2010-10-01
  • 作者简介:贾宁(1956- ),1982年毕业于武汉水利电力大学(现武汉大学),高级工程师,高级技师,电话:025-85055126.

Analysis of corrosive causes for copper alloy in low-pressure heater

Jia Ning1, Fu Lijuan2   

  1. 1. Nanjing Thermal Power Plant, Nanjing 210035, China;
    2. Northeast Electric Power College, Jilin 132012, China
  • Received:2004-05-17 Online:2004-09-20 Published:2010-10-01

摘要:

南京热电厂5#机组凝结水在流经低压加热器后,水中含铜量明显升高,针对这一问题,从金属电化学腐蚀的原理出发,探讨了低压加热器铜管腐蚀的原因,提出了降低腐蚀的方法,并进行了卓有成效的实践。

关键词: 低压加热器铜管, 腐蚀, 加药点, 联氨

Abstract:

The copper concentration goes up distinctly after the condensate of set No.5 in Nanjing Thermal Power Plant passing through the low-pressure heater. In order to resolve this problem, the causes for that from the view of metallic electrochemical theories, have been discussed, and the methods to reduce the corrosion in practice are presented. The practice proves to be efficient.

Key words: the copper tube of low-pressure heater, corrosion, the point of adding chemicals, hydrazine