INDUSTRIAL WATER TREATMENT ›› 2002, Vol. 22 ›› Issue (3): 35-37. doi: 10.11894/1005-829x.2002.22(3).35
Previous Articles Next Articles
YU Ping1, LUO Yunbai1, XU Guanghui2
Received:
Online:
Published:
于萍1, 罗运柏1, 许光辉2
作者简介:
Abstract:
The chemical condition of cooling water in operation has been adjusted in weak acid ion exchange treatment fed to prevent the cooling water system from scaling.Experimental results in laboratory and power plant are very satisfactory.
Key words: weak acid ion exchange treatment, circulation cooling water, scale prevention
摘要:
从调节循环冷却水的水化学工况入手,防止以弱酸床处理水作为循环冷却水补充水系统的结垢与腐蚀。实验室及现场运行试验结果表明,该方法行之有效。
关键词: 弱酸离子交换处理, 循环冷却水, 防垢
CLC Number:
TQ085+.4
YU Ping, LUO Yunbai, XU Guanghui. Prevention the cooling water system from scaling by using weak acid ion exchanger[J]. INDUSTRIAL WATER TREATMENT, 2002, 22(3): 35-37.
于萍, 罗运柏, 许光辉. 弱酸床处理循环冷却水系统防垢试验研究[J]. 工业水处理, 2002, 22(3): 35-37.
/ / Recommend / Download Citations
URL: https://www.iwt.cn/EN/10.11894/1005-829x.2002.22(3).35
https://www.iwt.cn/EN/Y2002/V22/I3/35