Abstract:
Through a series of experiments,the effect of corrosion inhibitive performance of TS-240on copper materials,either when the ferrous sulfate membranes are complete or incomplete,has been studied.The experimental results and applied effects show that TS-240 has no influence on the ferrous sulfate membranes.And,when the ferrous sulfate membrane is incomplete,TS-240 has excellent corrosion inhibitive performance for copper materials.
Key words:
membrane making,
corrosion rate,
ferrous sulfate
摘要:
通过一系列试验,研究了在硫酸亚铁膜完整和不完整两种条件下,TS-240对铜材的缓蚀性能。试验结果和现场应用效果表明,TS-240对硫酸亚铁膜不造成影响,而且在硫酸亚铁膜不完整条件下,TS-240对铜材有优良的缓蚀性能。
关键词:
造膜,
腐蚀率,
硫酸亚铁
CLC Number:
Zhao Weidong, Yang Qingchun. Researches on the corrosion inhibitive performance of TS - 240 under the condition of making ferrous sulfate membranes[J]. INDUSTRIAL WATER TREATMENT, 2005, 25(9): 64-65.