INDUSTRIAL WATER TREATMENT ›› 2005, Vol. 25 ›› Issue (9): 71-74. doi: 10.11894/1005-829x.2005.25(09).71

Previous Articles     Next Articles

Enhanced coagulation effect of fluorine-containing was tewater in the color television kinescope factory

Zhu Jia1, Wang Junling2, Chen Zhonglin1, Du Hong1, Wang Baozhen1   

  1. 1. School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China;
    2. Iron Works, Tangshan Steel Co., Tangshan 063000, China
  • Received:2005-04-29 Online:2005-09-20 Published:2010-10-01

彩管厂含氟废水的强化混凝处理效果研究

朱佳1, 王俊岭2, 陈忠林1, 杜红1, 王宝贞1   

  1. 1. 哈尔滨工业大学, 市政环境工程学院, 黑龙江哈尔滨 150090;
    2. 唐山钢铁公司炼铁厂, 河北唐山 063000
  • 作者简介:朱佳(1965- ),1988 年毕业于吉林建筑工程学院,高级工程师,哈尔滨工业大学博士研究生,联系电话: 0755-81069095,13802201050,E-mail:zhujia65@963.net

Abstract:

Aiming at the problems of conventional treatment of fluorine-containing wastewater in color television kinescope factory,an experiment on the enhanced coagulation treatment by sludge recirculation is carried out.The experimental results in lab and full-scale running showthat the sludge recirculation has enhanced the coagulation of fluorine-containing wastewater and got a good treatment effect.The fluoride of effluent water can be controled at a level of below 10.5 mg/L,and the fluoride in discharged water of the color television kinescope factory is stabilized at 4—6 mg/L.Compared with the conventional treatment process,the enhanced coagulation process do not need to dose calcium chloride,and it reduces the lime dosage 40%,reduces half sludge production,saves the coagulant 75%—80%,and increases the sedimentation efficiency 50%.The treatment cost reduces from2.75 yuan/m³ to 1.35 yuan/m³ and gets a considerable economic benefits.

Key words: fluorine-containing wastewater, ferric chloride, enhanced coagulation, sludge recirculation

摘要:

针对彩管厂含氟废水常规处理工艺存在的问题,提出了合理的污泥回流强化混凝处理工艺,并在实验室小试研究和实际生产运行中取得了很好的处理效果,出水F-质量浓度控制在10.5 mg/L以下,工厂混合后的排放水F-质量浓度基本稳定在4—6 mg/L。同时,省去了氯化钙投药系统,石灰用量比原来减少40%,产污泥量减至原来的一半,混凝剂用量减至原来的1/5—1/4,沉淀效率比原来提高50%,处理成本则由2.75元/m³降至1.35元/m³,取得了显著的经济效益。

关键词: 含氟废水, 三氯化铁, 强化混凝, 污泥回流

CLC Number: