INDUSTRIAL WATER TREATMENT ›› 2007, Vol. 27 ›› Issue (4): 57-60. doi: 10.11894/1005-829x.2007.27(4).57

Previous Articles     Next Articles

Study on the thermodynamic analysis of zinc scale in the washing water system of blast furnace gas and its treatment technology

Wang Xueben1, Wang Qingsheng2, Wu Zuocheng3   

  1. 1. Shandong Lianyou Petroleum and Chemistry Co. , Ltd. , Jinan 250001, China;
    2. Chinese Research Academy of Environmental Science, Beijing 100012, China;
    3. Tianjin Hydroelectric Plant, Tianjin Iron Metallurgy Group Co. , Shexian 056404, China
  • Received:2006-12-15 Revised:2006-12-15 Online:2007-04-20 Published:2010-10-01

高炉煤气洗涤水锌垢的热力学分析及处理技术

王学本1, 王庆生2, 吴作成3   

  1. 1. 山东联友石化工程有限公司, 山东 济南 250001;
    2. 中国环境科学研究院, 北京 100012;
    3. 天津天铁冶金集团公司水电厂, 河北 涉县 056404
  • 作者简介:王学本(1973- ),1995 年毕业于西北大学化学工程系,工程师, 电话:0531-88833637,E-mail: wangxueben@sina.com。

Abstract:

Aiming at the problem of forming Zn scale easily in the washing water system of blast furnace gas at Tianjin Iron Works, as viewed from thermodynamics, and by using the principle and data of thermodynamics, the analysis of chemical thermodynamics has been carried on.The cause of Zn scale formation in the washing water system is found theoretically.An experiment by using composite flocculant and complex water quality stabilizer are conducted.The new technology is suitable for removing the Zn scale in the washing water system of blast furnace gas. The result shows that the new type of water quality stabilizer has very good treatment efficiency.

Key words: washing water system of the blast furnace gas, zinc scale, thermodynamic analysis

摘要:

针对天津铁厂高炉煤气洗涤水系统容易形成锌垢的问题,从热力学角度,利用有关热力学原理和数据,进行了化学热力学分析,从理论上找出洗涤水系统的锌垢成因。采用复配絮凝剂和复合水质稳定剂进行了试验,研究出适合于高炉煤气洗涤水系统的锌垢去除新技术。试验结果表明,新型的水质稳定剂完全达到了良好的处理效果。

关键词: 高炉煤气洗涤水, 锌垢, 热力学分析