INDUSTRIAL WATER TREATMENT ›› 2000, Vol. 20 ›› Issue (4): 1-5. doi: 10.11894/1005-829x.2000.20(4).1

    Next Articles

The some factors of affecting water treatment chemicals used to control carbon steel corrosion in cooling water

LI Bengao1, YU Zhengqi1, ZHANG Yimei2   

  1. 1. Research Institute of Petroleum Processing Under SINOPEC, Beijing 100038, China;
    2. Shanghai Baoshan Steel and Iron Industry Corp., Shanghai 201900, China
  • Received:1999-12-03 Online:2000-04-20 Published:2010-10-01

影响循环水处理剂缓蚀效果的因素

李本高1, 余正齐1, 张宜莓2   

  1. 1. 中国石油化工集团公司水处理中心, 北京 100083;
    2. 上海宝山钢铁集团公司能源部, 上海 201900
  • 作者简介:第一作者李本高, 1959 年生, 1982 年获大连理工大学学士学位, 1988 年获北京化工大学硕士学位, 1997 年任中国石化集团公司水处理中心主任, 教授级高工。

Abstract:

8 typical kinds of water treatment chemicals used to control steel corrosion in circulating cooling water are investigated by using weight-loss tests.The results show that 5 factors such as the concentration of water treatment agents, calcium hardness and alkalinity, turbidity, the concentration of ironic ions and biocides have different corrosion inhibiting effects on different type of water treatment chemicals.

Key words: circulating water, corrosion, corrosion inhibitor

摘要:

通过NMR仪对国内外在中国使用的 8类典型的水处理剂的主要成分进行分析,由主要成分确定药剂类型;并采用旋转挂片腐蚀试验方法对这些水处理剂的缓蚀效果进行研究,发现药剂的自身浓度,水质钙硬和碱度、浊度、铁离子浓度以及杀菌剂对不同类型水处理剂的缓蚀效果影响是不同的,因此,应根据水处理剂的类型确定使用条件。

关键词: 循环水, 腐蚀, 缓蚀剂