Abstract:
This study is focused on the feasibility that utilized the sealed spectrophotometer to measure the CODCr of bleaching effluent. The results of t-test demonstrates that it can be used for the measurement of CODCr the same as the method described in standard method,and the Pearson coefficient is 0.999 5.
Key words:
spectrophotometer,
bleaching effluent,
sealed tube method,
COD
摘要:
探讨了密闭式分光光度法测定漂白废水的可行性,t—检验的结果表明,该方法与目前采用的CODCr标准方法测定结果无显著差异,泊松相关系数为 0.9995。
关键词:
分光光度,
漂白废水,
密闭式,
COD
CLC Number:
LI Qun, YANG Zhenhai, ZHANG Yelu, HU Kaitang, TAN Guomin. CODCr measurement of bleaching effluent with spectrophotometer[J]. INDUSTRIAL WATER TREATMENT, 2001, 21(5): 30-31.
李群, 杨振海, 张业录, 胡开堂, 谭国民,. 密闭式分光光度法测定漂白废水CODCr[J]. 工业水处理, 2001, 21(5): 30-31.