INDUSTRIAL WATER TREATMENT ›› 2013, Vol. 33 ›› Issue (7): 39-42.

Previous Articles     Next Articles

Pilot research on the treatment of reverse osmosis concentrated water by forced outer-circulation and triple-effect evaporation combined process

Guo Jie, Zhou Yuxiang, Tian Lihui, Guo Yanli, Zou Hong   

  1. CNOOC Shandong Chemical Engineering Co., Ltd.,Ji’nan 250101,China
  • Revised:2013-04-16 Online:2013-07-20 Published:2013-07-25

强制外循环三效蒸发反渗透浓水的中试研究

郭杰, 周玉香, 田立辉, 郭艳丽, 邹红   

  1. 中海油山东化学工程有限责任公司,山东济南 250101
  • 作者简介:郭杰(1964-),高级工程师。E-mail:sdjngj@126.com。
  • 基金资助:

    中国海洋石油总公司科技发展项目(C/KJFHG008-2009)

Abstract:

A pilot-plant of forced outer-circulation,triple-effective evaporation and crystallization treatment technology has been designed and established,by using the residual heat,while methylamine was synthesized in the urea unit,for treating reverse osmosis concentrated water.Based on experimental data,the operation parameters and running efficacy of every effective evaporator are investigated. Furthermore,its running costs are analyzed. The results show that when the operating pressure of every evaporator and the final condenser are -0.01- -0.02,-0.05- -0.06,-0.07- -0.08,-0.085 MPa respectively,the unit consumption ratio of steam is about 0.43,and the conductivity of steam condensate is below 200 μS/cm.These results indicate that it could be reused as make-up water in circulating cooling water systems or for desalted water stations.

Key words: residual heat, reverse osmosis concentrated water, forced outer-circulation, triple-effective evaporation, crystallization

摘要:

利用尿素生产过程中甲胺合成时的余热处理反渗透浓水,设计并建造一套强制外循环三效蒸发结晶处理工艺中试装置,结合试验数据考察各效蒸发器操作参数及运行效果,并对其运行成本进行分析。结果表明,当一、二、三效蒸发器及终冷凝器操作压力分别为-0.01~-0.02、-0.05~-0.06、-0.07~-0.08、-0.085 MPa时,单位蒸汽消耗比约为0.43,蒸发冷凝液电导率≤200μS/cm,可作为脱盐水站或循环水装置补水利用。

关键词: 余热, 反渗透浓水, 强制外循环, 三效蒸发, 结晶

CLC Number: