Abstract:
The Fe3O4/Na2S2O8 system catalytic oxidation process has been used for treating landfill leachate bio-chemical tail water. The influences of the factors,such as the dosages of Na2S2O8 and Fe3O4,pH,reaction time,etc. on the treatment effects are studied. The results show that when pH is 3,m(S2O82-):12m(COD)=1.2,Fe3O4 dosage 1.5 g/L,and reaction time 24 h,the removing rates of COD and chroma are 63% and 100%,respectively. Fourier transform infrared(FTIR) spectroscopy analytical results show that the contents of small molecular organic substances in Fe3O4/Na2S2O8 system are obviously reduced,compared with that of small molecular organic substances in untreated water samples.
Key words:
leachate biochemical tail water,
Na2S2O8,
Fe3O4,
catalytic oxidation
摘要:
采用Fe3O4/Na2S2O8体系催化氧化处理垃圾渗滤液生化尾水,研究了Na2S2O8与Fe3O4投加量、pH、反应时间等因素对处理效果的影响。结果表明,在pH=3,m(S2O82-):12m(COD)=1.2,Fe3O4投加量为1.5 g/L,反应时间为24 h的条件下,COD与色度去除率分别为63%和100%。FTIR分析结果表明,Fe3O4/Na2S2O8体系的小分子有机物含量比未处理水样小分子有机物含量有所降低。
关键词:
渗滤液生化尾水,
Na2S2O8,
Fe3O4,
催化氧化
CLC Number:
Zhang Qi, Zhan Peng, Nie Fahui, Hu Song, Liu Zhanmeng. Experimental study on the treatment of landfill leachate biochemical tail water by the Fe3O4/Na2S2O8 system[J]. INDUSTRIAL WATER TREATMENT, 2016, 36(6): 43-46.
张琪, 占鹏, 聂发辉, 胡松, 刘占孟. Fe3O4/Na2S2O8体系处理垃圾渗滤液生化尾水的实验研究[J]. 工业水处理, 2016, 36(6): 43-46.