INDUSTRIAL WATER TREATMENT ›› 2017, Vol. 37 ›› Issue (8): 93-97. doi: 10.11894/1005-829x.2017.37(8).093

Previous Articles     Next Articles

Experimental study on the determination of silica content in circulating cooling and boiler wat

Zhou Ying1, Bai Ying2, Lin Jihua1   

  1. 1. Ningbo Special Equipment Inspection and Research Institute, Ningbo 315048, China;
    2. CenerTech Tianjin Chemical Research & Design Institute Co., Ltd., Tianjin 300131, China
  • Received:2017-06-30 Online:2017-08-20 Published:2017-09-04

循环冷却水与锅炉用水中硅含量测定的实验研究

周英1, 白莹2, 林骥华1   

  1. 1. 宁波市特种设备检验研究院, 浙江宁波 315048;
    2. 中海油天津化工研究设计院有限公司, 天津 300131
  • 作者简介:周英(1957-),教授级高级工程师。电话:13905740453,E-mail:nbzhouying@126.com。

Abstract: Through a series of experiments,the influences of all the interference factors in the determination of or-dinary amount of silicon and trace amount of silicon are discussed. The measures to avoid interference and rele-vant suggestions are proposed. Experimental bases are provided for revising the Water for Industrial Circulating Cooling System and Boiler:Determination of Silica(GB/T 12149-2007).

Key words: silicon, circulating cooling water, boiler water, interference influence

摘要: 过一系列实验探讨了常量硅和微量硅测定时各干扰因素的影响,提出了避免干扰的措施及相关建议,为修订GB/T 12149-2007《工业循环冷却水和锅炉用水中硅的测定》提供了实验依据。

关键词: 硅, 循环冷却水, 锅炉用水, 干扰影响

CLC Number: