INDUSTRIAL WATER TREATMENT ›› 2017, Vol. 37 ›› Issue (9): 30-33. doi: 10.11894/1005-829x.2017.37(9).030

Previous Articles     Next Articles

Experimental study on the purification of oil-bearing wastewater by a new type of electric-flocculation device

Yang Jie1,2, Liu Yang1,2, Chen Mingcan1,2, Deng Zhanfei3, Jiang Wenming1,2, Chen Yimei1,2, Wang Zhansheng4   

  1. 1. Shandong Provincial Key Laboratory of Oil & Gas Storage and Transportation Safety, Qingdao Key Laboratory of Sea Oil & Gas Storage and Transportation Technology, Qingdao 266580, China;
    2. College of Storage and Transportation and Civil Engineering, China University of Petroleum, Qingdao 266580, China;
    3. Changqing Oilfield Company Planning Department, Xi'an 710018, China;
    4. Science and Technology Department, Liaohe Oilfield Bureau, Panjin 124000, China
  • Revised:2017-06-06 Online:2017-09-20 Published:2017-09-28

新型电絮凝装置净化含油污水的试验研究

杨杰1,2, 刘杨1,2, 陈明灿1,2, 邓展飞3, 蒋文明1,2, 陈义美1,2, 王占胜4   

  1. 1. 山东省油气储运安全省级重点实验室, 青岛市环海油气储运技术重点实验室, 山东青岛 266580;
    2. 中国石油大学(华东)储运与建筑工程学院, 山东青岛 266580;
    3. 长庆油田分公司规划计划处, 陕西西安 710018;
    4. 辽河油田局机关科技处, 辽宁盘锦 124000
  • 通讯作者: 蒋文明,副教授。E-mail:jiangwenming@upc.edu.cn。 E-mail:jiangwenming@upc.edu.cn
  • 作者简介:杨杰(1992-),硕士。E-mail:865651148@qq.com。
  • 基金资助:
    国家自然科学基金项目(51406240);山东省自然科学基金项目(ZR2014EEQ003);中央高校基本科研业务费专项资金(14CX02211A/12CX04070A)

Abstract: According to the water characteristics of oilfield emulsion,the research on dynamic tests of the prepared oil-bearing wastewater has been carried out by electric-flocculation method. Based on a self-designed new type of electro-flocculation(EF)device,the tests of the influences of current density and treatment flow rate on the treat-ment performances of the new electro-flocculation device have been conducted firstly. It is found that with the in-crease of current density and the decrease of treatment flow rate,the oil removing rate and turbidity removing rate are increased. Secondarily,after the inclined tubes have been added to the new type of electro-flocculation de-vice,the oil removing rate is increased by 2%-3%. At the end,the aluminum consumption and electric power consumption are analyzed. It is found that when the current density is 95.24 A/m2,and treatment flow rate is 20 L/h, the treatment effect of the device is the best.

Key words: electro-coagulation, oily wastewater, dynamic test, treatment performance

摘要: 针对油田乳化液的水质特性,用电絮凝方法对配制的含油污水进行动态试验研究。基于自主设计的新型电絮凝装置,首先开展了电流密度和处理流量对新型电絮凝装置处理性能的影响试验,发现随着电流密度的增大和处理流量的减小,除油率和除浊率升高。其次,在新型电絮凝装置中增加了斜管装置,发现除油率提高了2%~3%。最后,分析了耗铝量和耗电量,发现电流密度为95.24 A/m2,处理流量为20 L/h时,装置处理效果最佳。[关键词]电絮凝;含油污水;动态试验;处理性能