摘要:
染料废水水质复杂,常规工艺很难处理。以河北某生产染料化工厂的废水为对象,对其处理工艺进行了试验研究。结果表明,采用“PFS+MS”两步混凝+水解酸化+生物接触氧化+炉渣吸附工艺处理染料废水取得了良好的效果。处理后色度由原水的11111倍降至80倍,COD由Cr7762mg/L降至310mg/L,去除率分别为99.3%96.0%。
关键词:
染料废水,
二级混凝,
水解酸化,
生物接触氧化
Abstract:
Owing to its highly concentrated chroma and complicated organic ingredients,dyeing wastewater from a chemical plant in Hebei has been studied and a good result id obtained after using the treatment technocs of PFS+MS two stages of coagulation -hydrolysis -contact oxidation -slag adsorption.After this tratment,the chroma of the wastewater drops form 11111 to 80,the CODCrfrom 7762mg/L to 310mg/L,and the rremoval rate is 99.3% and 96.0% respectively.
Key words:
dyeing wastewater ,
second grade-coageulation ,
huudrolysis-acidification,
biocontact oxidation
中图分类号:
崔巍, 林海, 温晓龙. “混凝+生化”处理高浓度染料废水的试验研究[J]. 工业水处理, 2005, 25(3): 56-59.
Cui Wei, Lin Hai, Wen Xiaolong. Experiental research on the highly concentrated dyeing wastewater treatment by the coagulation -biochemical technique[J]. INDUSTRIAL WATER TREATMENT, 2005, 25(3): 56-59.