工业水处理 ›› 2008, Vol. 28 ›› Issue (1): 50-53.

• 试验研究 • 上一篇    下一篇

混凝—微电解预处理维生素B1生产废水

贾仁勇, 孙力平, 王妍   

  1. 天津城市建设学院环境与市政工程系 天津 300384
  • 收稿日期:2007-07-17 修回日期:2007-07-17 出版日期:2008-01-20 发布日期:2010-10-01
  • 作者简介:贾仁勇(1981-),天津城市建设学院硕士研究生,研究方向:污水资源化.电话:13622150221,E-mail: jiarenyong@126.com.

Pretreating of wastewater from vitamin B1 production by coagulation - micro-electrolysis process

Jia Renyong, Sun Liping, Wang Yan   

  1. Tianjin Institute of Urban Construction,Tianjin 300384,China
  • Received:2007-07-17 Revised:2007-07-17 Online:2008-01-20 Published:2010-10-01

摘要:

针对维生素B1生产废水成分复杂、难于生化降解、水质不稳定、固体悬浮颗粒含量高的特点,采用混凝—微电解法进行预处理。当混凝剂三氯化铁的投加质量浓度为150mg/L,微电解反应器内pH为4.2,反应时间为50min时,出水TOC和COD的去除率分别达到77.4%和82.3%,对SS的去除率也达95%,同时有效提高了废水的可生化性。

关键词: 维生素B1生产废水, 混凝, 微电解, 预处理

Abstract:

Coagulation - micro-electrolysis process has been used for pretreating the wastewater from vitamin B1 production,which is characterized by complicated composition,refractory,unstable quality and high suspended solids. When the coagulant,ferric chloride,dosage is 150 mg/L,the pH in the micro-electrolytic reactor is 4.2,and reacting time is 50 min,the removal rates of TOC and COD are 77.4% and 82.3% respectively,the SS removal rate gets to 95%,and at the same time the biodegradability of wastewater is improved distinctly.

Key words: wastewater from vitamin B1 production, coagulation, micro-electrolysis, pretreatment

中图分类号: