Abstract:

In thermal power plants, boiler water is treated widely with ion exchange resin. The causes, harm and treating methods of ion exchange resin entering into the boiler are analyzed. It is very significant to ensure the safety and economic operation of the thermal equipment.

Key words: ion exchange resin, water treatment, boiler, corrosion

摘要:

在火力发电厂,锅炉用水广泛采用离子交换树脂进行处理.作者分析了离子交换树脂进入锅炉的原因、危害及处理方法,对保证热力设备的安全经济运行具有重要意义.

关键词: 离子交换树脂, 水处理, 锅炉, 腐蚀