INDUSTRIAL WATER TREATMENT ›› 2014, Vol. 34 ›› Issue (6): 75-77. doi: 10.11894/1005-829x.2014.34(6).075

Previous Articles     Next Articles

Detection of ammonia-nitrogen in water on base of electrodialysis ion transition

Wang Yuan, Yang Huizhong   

  1. Key Laboratory of Advanced Process Control for Light Industry, Division of Education, Jiangnan University, Wuxi 214122, China
  • Received:2014-04-08 Online:2014-06-20 Published:2014-07-05

基于电渗析离子转型的氨氮检测研究

王远, 杨慧中   

  1. 江南大学轻工过程先进控制教育部重点实验室, 江苏无锡 214122
  • 通讯作者: 杨慧中,E-mail:yhz_jn@163.com E-mail:yhz_jn@163.com
  • 作者简介:王远(1988-),硕士。电话:15861425528,E-mail:wangyuan54@126.com
  • 基金资助:

    国家自然科学基金项目(60674092)江苏省环保科研课题(2012051)江苏省产学研前瞻性联合研究项目(BY2012070)

Abstract: A method for the detection of ammonia-nitrogen in water on base of electrodialysis ion transition has been presented. The method is carried out on base of electrode determination, by using electrodialytic electrolysis principles, producing strong-alkaline electrolytic water through decomposing deionized water, and then mixing with the water samples to be tested. The experimental results show that for the detection of ammonia-nitrogen in the range of 0.1-10 mg/L, the relative standard deviation is less than 4%, the standard recovery rate is between 97% and 105%, and the deviation is within 4% compared with the international standard method. The method can meet the requirements of on-line analysis test.

Key words: ammonia-nitrogen, electrodialysis, strong-alkaline electrolytic water, ammonia gas-sensitive electrode

摘要: 提出了一种基于电渗析离子转型的水质氨氮检测方法。该方法以电极测定法为基础,利用电渗析电解原理,通过离解去离子水生成强碱性电解水,再与待测水样混合进行测定。实验结果表明:该方法检测0.1~10 mg/L范围内的氨氮,相对标准偏差<4%,加标回收率在97%~105%,相对于国标法的偏差在4%以内,满足在线分析测试的要求。

关键词: 氨氮, 电渗析, 强碱性电解水, 氨气敏电极

CLC Number: