INDUSTRIAL WATER TREATMENT ›› 2002, Vol. 22 ›› Issue (9): 38-40.

Previous Articles     Next Articles

Amplification test of treating industrial circulating water with ozone

SHI Lei1, SHI Yan2   

  1. 1 Shengli Oil field Petrochemical Works,Dongying 257000,China;
    2 Shengli Oil field Supply Department,Dongying 257000,China
  • Received:2001-12-17 Online:2002-09-20 Published:2010-10-01

臭氧处理工业循环水试验研究

石磊1, 石岩2   

  1. 1 胜利油田石油化工总厂,山东,东营,257000;
    2 胜利油田供应处,山东,东营,257000
  • 作者简介:石磊(1963-),1986年毕业于石油大学机械系,供排水车间主任,高级工程师.

Abstract:

The practical effects of corrosion control,scale prevention and bacteria killing of industrial circulating water being treated with ozone alone or combined with corrosion inhibitor of molybdenum or phosphorus series have been observed. The effect and problems of using ozone through the course and phenomenon of the test as well as the data obtained have been observed. Some experience for further work is provided.

Key words: ozone, circulating, water test

摘要:

通过利用臭氧单独以及与钼系缓蚀药剂、磷系缓蚀药剂配合处理工业循环水,观察其缓蚀、阻垢、杀菌的实际使用效果,从试验过程及现象和数据中找出臭氧在实际使用中能达到的效果和存在的问题,为今后进-步试验提供-些经验.

关键词: 臭氧, 循环水, 试验

CLC Number: