INDUSTRIAL WATER TREATMENT ›› 2007, Vol. 27 ›› Issue (3): 49-52. doi: 10.11894/1005-829x.2000.20(4).49

Previous Articles     Next Articles

Study on continuous treatment of phenol-bearing was tewater from coking plant by microemuls ion membrane

Zhou Furong, Du Jinping, Wan Kun   

  1. School of Chemistry and Environmental Engineering, Jianghan University, Wuhan 430056, China
  • Received:2006-10-20 Online:2007-03-20 Published:2010-10-01

微乳液膜连续处理焦化厂含酚废水的试验研究

周富荣, 杜金萍, 万昆   

  1. 江汉大学化学与环境工程学院, 湖北武汉 430056
  • 作者简介:周富荣(1964- ), 1986 年毕业于郑州轻工业学院化工系, 副教授。电话: 027-62268590, E-mail: hhyzfr@sina.com或hhyzfr@jhun.edu.cn。
  • 基金资助:

    武汉市科技攻关计划资助项目(20025007170)

Abstract:

Based on the continuous experiments of the treatment of phenol-bearing wastewater in coking plant by microemulsion membrane,the influential effects of agitating strength,the ratio of microemulsion to wastewater,running time,oil recycling,etc. on phenol removing rate are discussed. The results show that the microemulsion membrane with Span80 as surfactant and P204 as carrier can be used to treat phenol-bearing wastewater. After a two-stage treatment,the phenol content in the wastewater is lower than the national discharge standard. Its mass transfer speed is fast,phenol removing rate is high and the oil can be recycled. Its process is simple and has good running stability.

Key words: microemulsion membrane, phenol, wastewater treatment

摘要:

通过微乳液膜法处理焦化厂含酚废水的试验研究,探讨了搅拌强度、乳水比、运行时间、油相回用次数等因素对除酚率的影响。试验结果表明,采用Span80为表面活性剂、P204为载体的微乳液膜处理含酚废水,经过二级处理后的废水含酚量低于国家排放标准。该法不仅传质速率快,除酚效率高,油相可重复使用,而且工艺简单,运行稳定性好。

关键词: 微乳液膜, 酚, 废水处理

CLC Number: