工业水处理 ›› 2003, Vol. 23 ›› Issue (2): 56-58. doi: 10.11894/1005-829x.2003.23(2).56

• 水处理工程 • 上一篇    下一篇

厌氧-气浮-A/O接触氧化工艺处理洗毛废水

许闽明   

  1. 广东省佛山市环境工程装备有限公司 广东佛山 528000;
  • 收稿日期:2002-10-18 出版日期:2003-02-20 发布日期:2010-10-01
  • 作者简介:许闽明(1971- ), 1993 年毕业于厦门大学, 获学士学位, 工程师。电话:0757-3355842

Application of anaerobic -air floation -A O contacted oxidation process to the treatment of wool scouring wastewater

Xu Minming   

  1. Foshan Environmental Engineering Equipment Co., Ltd.,Foshan 528000,China
  • Received:2002-10-18 Online:2003-02-20 Published:2010-10-01

摘要:

介绍了厌氧-气浮-A O接触氧化工艺处理洗毛废水的应用情况。在进水CODCr和BOD5分别达到26565mg L和6478mg L的情况下,出水平均值分别为50.58mg L和9.82mg L,平均去除率均达到99.8%。

关键词: 洗毛废水, 处理工艺, 厌氧, 接触氧化

Abstract:

The application of anaerobic-air floation-A O contacted oxidation technology to the treatment of wool scour-ing wastewater has been described in detail .It is indicated that the average removal rates of CODCr and BOD5 both reach 99.8%, whereas CODCr and BOD5 of the influent has a level of 26 565mg L and 6 478 mg L,CODCrand BOD5 of the drain has a level of 50.58 mg L and 9 .82 mg L, respectively .

Key words: wool scouring wastewater, treatment technology, anaerobic, contacted oxidation

中图分类号: