工业水处理 ›› 2003, Vol. 23 ›› Issue (6): 28-30. doi: 10.11894/1005-829x.2003.23(6).28

• 试验研究 • 上一篇    下一篇

铁屑法处理电镀含铬废水的试验及应用

谢少雄, 黄功浩, 黄美燕   

  1. 汕头大学化学系 广东汕头 515063
  • 收稿日期:2002-10-14 出版日期:2003-06-20 发布日期:2010-10-01
  • 作者简介:谢少雄(1966- ),1987年毕业于广东工业大学,讲师。

Test of the treatment of chromiun-containing wastewater from electroplating by iron filing method and its application

Xie Shaoxiong, Huang Gonghao, Huang Meiyan   

  1. Chemical Department, Shantou University, Shantou 515063, China
  • Received:2002-10-14 Online:2003-06-20 Published:2010-10-01

摘要:

介绍了一种处理电镀含铬废水的方法———铁屑法,就该法对六价铬去除率的影响因素:pH、铁屑用量、搅拌时间进行了静态试验,得到了较佳的反应工艺参数。在静态实验的基础上,研究了以铁屑为填料的反应柱动态处理废水的效果,并成功地运用于电镀废水的实际处理。结果表明:六价铬的去除率达到99.9%以上,出水达到国家排放标准。

关键词: 铁屑, 电镀废水, 六价铬

Abstract:

A new method for treating chromium-containing wastewater from electroplating with iron filings is introduced.Aiming at the influential factors of this method on the removal rate of Cr(Ⅵ ),static tests are given to the pH value,theamount of iron filings,and the time for stirring.Technological parameters of the reactions have been obtained.On the basisof static tests,the effect of dynamic wastewater treatment by a reactive column which uses iron filings as feeding materialis studied.It is successfully used in practical treatment of electroplating wastewater.The results show that the removalrate of Cr(Ⅵ )is over 99.9 %,reaching national discharge standard.

Key words: iron filing, electroplating wastewater, Cr(Ⅵ )

中图分类号: